LED High Bay Light - Kernel Series - Reliability Test Part3
Model Tested: HB-K200W | Electric Rating: 100-277V, 50/60Hz | Test Date: 2019.6.21-2019.6.28
Test Standards and Test Results of Kernel Series LED High Bay Light
S/N | Test Item | Reference Standard | Result |
1 | Electrical parameter test | UL 1598/8750 | Pass |
2 | Hi-pot test | UL 1598/8750, TUV 60598 | Pass |
3 | Grounding test | UL1598, TUV 60598 | Pass |
4 | Surge protection test | IEC 61000-4-5, GB/T 17626.5 | Pass |
5 | Weight bearing test | UL 1598 | Pass |
6 | Drop test | GB/T 4857.5-92 | Pass |
7 | Sweep vibration test | IEC-EN: 60598 | Pass |
8 | Waterproof test | IEC-EN: 60598 | Pass |
9 | Salt spray test | GB/T 2423.17 | Pass |
10 | High ambient temperature test | UL 1598, IEC/EN: 60598 | Pass |
11 | Low ambient temperature test | UL 1598, IEC/EN: 60598 | Pass |
12 | On-off test | GB-T/24908-2010 | Pass |
13 | Aging test | Internal standard | Pass |
14 | High input voltage test | GB-T/24908-2010 | Pass |
15 | Low input voltage test | GB-T/24908-2010 | Pass |
16 | Insulation resistance test | GB7000.1-2015, IEC 60598-1:2014 | Pass |
17 | IK impact test | GB-T/2423.55 | Pass |
Test Sample Picture:
---Test Item 12. On-off Test---
-
Reference standard
GB-T/24908-2010
-
Test equipment
Timing relay device
-
Test condition
Test the sample at rated voltage
-
Test procedure
Turn on and turn off the light every 30 seconds, and the cycle is repeated for 8 hours.
-
Requirement
The LED High Bay Light can work normally with no malfunction
-
Test results
Model No. | Test Date | Result |
HB-K200W | 2019.6.27 | Pass |
-
Test pictures
---Test Item 13. Aging Test---
-
Reference standard
Internal quality assurance standard
-
Test equipment
Power meter, voltage regulator
-
Test procedure
Keep the sample working continuously for 48 hours
-
Requirement
The high bay lights can work normally with no malfunction
Model No. | Test Condition | Test Date | Result |
HB-K200W | 25±1℃ | 2019.6.20-2019.6.22 | Pass |
-
Test pictures
---Test Item 14. High Input Voltage Test---
-
Reference standard
GB-T/24908-2010
-
Test equipment
Power meter, voltage regulator
-
Test procedure
Set the input voltage to AC305V, which means AC277V + 10%, light it up for 8 hours and then turn it to the rated voltage to light up for 15 minutes to check the performance of the industrial led light fixtures
-
Requirement
The LED High Bay Light can work normally with no malfunction like flicker or defective LEDs
Model No. | Test Condition | Test Date | Result |
HB-K200W | Input voltage AC305V | 2019.6.25 | Pass |
-
Test pictures
---Test Item 15. Low Input Voltage Test---
-
Reference standard
GB-T/24908-2010
-
Test equipment
Power meter, voltage regulator
-
Test procedure
Set the input voltage to AC85V, which means AC100V - 15%, light it up for 8 hours and then turn it to the rated voltage to light up for 15 minutes to check the performance of the highbay led warehouse lights
-
Requirement
The LED High Bay Light can work normally with no malfunction like flicker or defective LEDs
Model No. | Test Condition | Test Date | Result |
HB-K200W | Input voltage AC85V | 2019.6.25-2019.6.26 | Pass |
-
Test pictures
---Test Item 16. Insulation Resistance Test---
-
Reference standard
GB-7000.1-2015 / IEC60598-1:2014
-
Test equipment
High voltage/Insulation resistance tester
-
Test Condition
Test voltage DC500V and last for 10 seconds
-
Test procedure
Connect one end of the tester to the lamp input, and the other to the lamp shell, set the parameters then test
-
Requirement
PCB can not be damaged and insulation resistance exceeds 1MΩ
Model No. | Test Voltage | Duration Time | Tested Resistance | Test Date | Result |
HB-K200W | DC500V | 10s | 3.99GΩ | 2019.6.26 | Pass |
-
Test pictures
---Test Item 17. IK Impact Test---
-
Reference standard
GB-T/2423.55
-
Test equipment
IK test platform
-
Test Condition
IK Code | IK00 | IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 |
Impact Energy (J) | a | 0.14 | 0.2 | 0.35 | 0.5 | 0.7 | 1 | 2 | 5 | 10 | 20 |
Equivalent Mass (kg) | / | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.5 | 1.7 | 5 | 5 |
Falling Height (mm) | / | 56 | 80 | 140 | 200 | 280 | 400 | 400 | 300 | 200 | 400 |
-
Test procedure
Install the impact part according to the IK level on the test instrument, and adjust it to the corresponding height. Fix the test sample in position, the distance between the end of the impact part and the measuring point should be 60mm±20 mm. Hit 5 times.
-
Requirement
There should be no damage or cracking on the impact surface of the LED High Bay Light
Model No. | Lamp Cover Material | IK Code | Impact Energy | Falling Height | Impact Times | Malfunction | Test Date | Result |
HB-K200W | Glass | IK07 | 2J | 400mm | 5 | No | 2019.6.26 | Pass |
PC | IK08 | 5J | 300mm | 5 | No | 2019.6.26 | Pass |
-
Test pictures